Module 9, lesson 6 of 6. 12 min read

Troubleshooting common faults: low generation, inverter errors, tripping

A step-by-step method for common rooftop faults: low generation, grid over-voltage, isolation faults, zero output and RCCB or MCB tripping.

Lessons in module 9

In this lesson you will

  • Apply a structured fault-finding method using data before tools
  • Diagnose low generation from string and time-of-day patterns
  • Resolve grid over-voltage and isolation-fault errors
  • Find the cause of RCCB and MCB tripping

Most service calls fall into a few patterns: "generation is low", "the inverter shows an error", "it keeps tripping", and "nothing at all". A structured method finds the cause quickly and safely, and avoids the expensive habit of replacing the inverter first. The golden rule: look at the data before you open a box.

The method

Fault-finding: from data to the faulty part 1 Ask and read dataapp history, error log 2 Find the patternwhen? which string? 3 Lookroof, cables, DBs 4 Measure safelyV, I, insulation 5 Split and isolatehalf the string, then half 6 Fix, re-test,record Most faults are found in steps 1–3. Replace parts only after step 5 points to them. Safety: PV is live in daylight; open isolators and check with a DC clamp before touching connectors.
  1. Ask and read data. When did it start? After rain, after cleaning, after a storm, after the DISCOM changed the meter? Pull up the app's daily curve and the inverter's error log.
  2. Find the pattern. Is it every day or only sometimes? At a particular time? On one string or all?
  3. Look. Walk the roof and open the DB covers (not the live terminals): shade, dirt, damaged cables, burnt connectors, red SPD windows, tripped devices.
  4. Measure voltages, currents and insulation, with the right instruments and safe isolation.
  5. Split and isolate. Halve the suspect circuit, test each half, and repeat.
  6. Fix, re-test and record the cause and the readings.

Low generation

Read the daily curve

The shape of the generation curve tells you a lot:

Curve shape Likely cause
Smooth bell, but lower than usual everywhere Soiling, haze, high temperature, or a whole string missing
Notch at the same time every morning or afternoon Shading from a tank, parapet, tree, LA mast or new building
Flat top at noon Clipping at the inverter's AC limit (normal if the DC/AC ratio is high), or export limiting
Sudden drops to zero around noon, then restarts Inverter tripping on grid over-voltage
Zero until late morning, then normal Insulation fault on wet mornings, clearing as the array dries

Compare strings

If the inverter shows per-MPPT or per-string data, compare them. Identical strings should be within a few percent.

  • One string low by about one module's share (say 10% on a 10-module string): a module with failed bypass diodes, a module shorted, or a heavily shaded module.
  • One string at zero: blown fuse, open connector, broken cable, or an open isolator pole.
  • One string voltage much lower than another: count the modules; a reversed module or a module short.

Worked example

A 6.5 kWp system (two strings of 6 × 545 Wp on two MPPTs) used to make about 28 kWh on clear April days and now makes about 25.5 kWh. The app shows MPPT 1 at 13.1 A and 230 V at noon; MPPT 2 at 13.0 A and 192 V.

MPPT 2's voltage is 38 V lower: almost exactly one module's Vmp at operating temperature (about 38 V). One module in string 2 is contributing nothing. On the roof, a thermal camera shows one module with a hot junction box: its bypass diodes have failed short. The loss of about 2.5 kWh a day matches one module out of twelve (28 ÷ 12 ≈ 2.3 kWh). Replacing the module under warranty restores the output.

Inverter error messages

Names differ by maker; the common families are:

Grid over-voltage / grid voltage out of range

The inverter has measured AC voltage above its trip limit. - Log the voltage at the meter at noon (a recording meter for a day is ideal). - Calculate the rise in your AC cable (module 6, lesson 4) and check terminal tightness. - If the grid itself is high, write to the DISCOM with your readings and ask for a transformer tap or feeder check. - Use the inverter's reactive-power or volt-watt functions if the DISCOM permits. - Never widen the trip limits beyond the DISCOM's settings.

Isolation fault / low insulation resistance ("PV ISO", "Riso low")

At start-up the inverter measures the array's insulation to earth; if it is below its limit, it will not connect. - Typical pattern: errors on wet mornings after rain, clearing by 10–11 am. - Isolate the strings and measure insulation resistance of each, + to earth and − to earth (lesson 3). - Split the bad string at its connectors and test each half to find the section. Common culprits: a connector lying in water, a cable pinched under a clamp or cut on a sharp frame edge, water in a junction box, a monkey-bitten cable.

No grid / islanding

The inverter cannot see the grid: check the ACDB MCB and RCCB, the main DB, a loose neutral, and whether there is an actual outage.

Over-temperature / derating

The inverter is reducing output to protect itself: check for sun on the inverter, blocked vents, dust-clogged heat sinks or a failed fan.

Arc fault (inverters with arc detection)

Treat it seriously: inspect every connector and joint on the string for scorching. Do not simply reset and leave.

Tripping

RCCB trips

  • Only on wet mornings, on a large array: natural leakage through module capacitance plus moisture can exceed a 30 mA device's threshold. Check the inverter manual's RCD recommendation (type and sensitivity, often 100 mA or 300 mA for larger arrays) and whether the inverter has internal residual-current monitoring.
  • At random times, also when the inverter is off: the fault is elsewhere in the building wiring, not the solar.
  • Wrong RCCB type (Type AC instead of Type A or B): replace with the type the manual specifies.

MCB trips

  • MCB rated too close to the inverter's maximum output current, or heating in a crowded DB in summer: check that the rating is at least 1.25 × maximum output current and that the DB is ventilated.
  • Loose terminals heating the MCB: look for discoloured plastic; re-terminate and torque.

SPD failed

After a storm, check SPD windows. A shorted SPD can trip the RCCB or blow its back-up fuse. Replace the cartridge with the same type and rating.

Key points

  • Read the data first: the app's daily curve and the error log reveal most faults.
  • Compare strings; a shortfall of one module's voltage points to a failed module or bypass diodes.
  • Grid over-voltage trips need voltage logging, cable rise calculations and DISCOM help, never wider trip limits.
  • Isolation faults on wet mornings mean moisture or insulation damage: test each string and split to locate.
  • RCCB trips on large arrays may be capacitive leakage; follow the inverter manual's RCD guidance.

Check yourself

  1. Output drops to zero around noon on sunny days and restarts after a few minutes. What is the likely cause?
  2. An inverter shows "Riso low" every morning after rain and runs normally by 11 am. What do you test, and how do you locate the fault?
  3. Two identical strings show 400 V and 362 V at the same time. What does the difference suggest?
Answers
  1. The inverter is tripping on grid over-voltage when export is highest; check grid voltage at the meter and the AC cable rise.
  2. Measure insulation resistance of each string (+ to earth and − to earth) when the fault is present, then split the bad string at its connectors to find the damp or damaged section.
  3. About 38 V less, roughly one module's Vmp: one module is not contributing (failed bypass diodes, short, or severe shading).